  • 1
  • 2

Brand Name : SUMT, ANT

Model Number : OMS-560-RHP-E-3T

Place of Origin : NINGBO CITY, CHINA

MOQ : MOQ:6sets

Price : USD100-140/PC

Payment Terms : T/T, Western Union, MoneyGram,Paypal

Supply Ability : 5000-1000pcs/month

Delivery Time : 3-20 working days depending on the quantity

Packaging Details : Box+carton, 6SETS/Carton, 24kg/carton, carton size: 45x34x36.5cm

Material : Stainless steel

Rated Load : max 3000kg

Voltage : DC19-29V

Cable length : 8m, 4 blank wire

Installation location : under the rope hitch plate

Display mode : Weight/percentage

Structure : Split type

Alarm relay output : 5(overload,full load,empty load, optical,acousti

Contact Now

SUMMIT Split type elevator weighing system3000kg RHP-E-OMS-560 mounting under the rope hitch plate elevator load control device

Installation loacation: Between wire rope hitch plates:OMS-560-UC-AP
Split Type Elevator Load Weigher 3000kg RHP-E-OMS-560 Elevator Load Control Device
Description:
The elevator over load control device OMS-560-RHP-E is one kind of split type load weighing solution ,and it consists of 1 or 2 pressure load sensor RHP-E and a controller OMS-560, and the pressure load cell is typically plated under the wire rope hitch plate. This method have no impact on the crossing height requirements and are there-fore especially suitable for new installation and modernization projects.
Features:

  1. Cost efficient and precise method
  2. Very easy to install
  3. Static load at fixing point(under the plate of wire rope attachment)
  4. Suitable for the new installations and modernization project
  5. Menu-guided operation
  6. 5 relays output overload,full,half empty,optical, audio output
  7. DIN Rail or on flat surface mounting with screws
  8. IP-65 rated plastic box.
  9. Integrated software to correct weight increases due to compensating chain.
  10. Display load as well as percentage
  11. Protecting important data from being disturbed by password
  12. Automatic correction of zero drift, makes the equipment in optimum stage
  13. Self-learning function, regulating high floor additional weight error
  14. Control equipment swap entirely,self-diagnosis and alarming
  15. Self-learning operating conducted by any fixed load

Control Unit:OMS-560
Operation Voltage AC/DC16-48V Sensor operation voltage DC5V
Nominal power 4W Signal Hold Voltage AC/DC12-45V
Input Channel (Load Cell ) 2 Measuring precision 0.1%
Relay Number

5(overload,full,half empty,optical, audio output)

Operation temperature -45degree-+85degree
Contact Load 8A250VAC,5A 250VAC,5A 30VDC Size 90x84x58mm
Display Type 4 digits 0.56 inch LED Weight 265g
Display mode Weight/percentage Shell material ABS


Model: RHP-E
Rated Load 3000kg/PC Output Resistance 700M+/-2 ohm
Rated Output 2.0+-0.02%mv/v Safe Overload 150% F.S.
Total error +/-0.5% F.S Ultimate Overload 200% F.S.
Repeatability +/-0.5% F.S. Construction material Stainless Alloy steel
Creep 30min +/-0.05% F.S/30min Protection Class IP68
Zero Balance +/-1% F.S. Insulation impedance ≥5000Ω
T C SPAN +/-0.02% F.S./10 degree Celsius Cable length 8m(black)
Operation temperature range -30 to 70 degree Celsius Connection type 4 bank wire
Input Resistance 760+/-10 ohm
Excitation
DC 5-12V


Wiring Diagram:
Split Type Elevator Load Weigher 3000kg RHP-E-OMS-560 Elevator Load Control Device
4 blank wires:
Split Type Elevator Load Weigher 3000kg RHP-E-OMS-560 Elevator Load Control Device
Installation location&Size:
Split Type Elevator Load Weigher 3000kg RHP-E-OMS-560 Elevator Load Control Device
Split Type Elevator Load Weigher 3000kg RHP-E-OMS-560 Elevator Load Control Device

Instruction:
The purpose of the SUMMIT Load Weighing system is to measure the load in the elevator and pro-vide usable information about the load to the elevator controller. This information is used forpre-torquing and for dispatching decisions, e.g. light load anti-nuisance, heavy load and over-load.
The system usually consists of a sensor or group of sensors mounted on the elevator’s some position such as clamping on wire rope, or under cabin, under the wire rope plate installation and a control unit. The sensor(s) provide a signal to the control unit directly related to the amount of load in the cab. The load weighing control accepts this signal and provides usable data to the elevator controller in the form of an analog signal and discrete relay contacts.


Product Tags:

Split Type Elevator Load Weigher 3000kg

      

Elevator Load Weigher RHP-E-OMS-560

      

RHP-E-OMS-560 Elevator Load Control Device

      
Quality Split Type Elevator Load Weigher 3000kg RHP-E-OMS-560 Elevator Load Control Device for sale

Split Type Elevator Load Weigher 3000kg RHP-E-OMS-560 Elevator Load Control Device Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Ningbo youte electric Co.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)